Certification: RoHS, CB, ISO9001, CE
Working Medium: R32
Heat Source Type: Air Source Heat Pump
Thermostat Factory Setting: 41/7
Thermostat Maximum Setting: 60/5
Ambient Working Temperature: -30c~45c
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
WWR32S-V
Heating Capacity
8kw-16kw
Unit Type
Inverter
Application Scope
Hotels,Clubs,Hospitals,Villas and etc
Transport Package
Factory Standard
Specification
995*410*800mm
Trademark
Wotech
Origin
China
HS Code
84186120

Product Description

R32 Full DC Inverter a+++ Air to Water Split Heat Pump for Heating Cooling and Hot Water
Features:

1.Hot water up to 65ºC,suitable for underfloor/radiator heating/fan coil

2.can work stable at ambient temperature -25C to 45C

3.E-Heater,diverter valve and water pump can be inclueded

4. A+++ Energy Rating Level

5.Full inverter system,Stable and efficient performance.

6.R32 System,environment friendly

7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water

8.With Wifi App control
R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water

Installation Diagram:
R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot WaterR32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water 



Technical Parameter:
Market model   WW08V-S WW10V-S WW12V-S WW14VM-S
Heating1 Output Capacity kW 3.40~8.65 3.70~10.30 4.95~12.46 5.92~14.94
Input Power  kW 0.59~1.65 0.62~2.05 0.90~2.48 1.15~3.20
COP - 5.23~5.72 5.02~5.90 5.03~5.50 4.67~5.12
Input Current A 2.82~7.92 2.96~9.81 4.31~11.85 5.50~15.3
Heating2 Output Capacity kW 3.43~7.77 3.90~9.84 4.37~12.43 5.18~14.30
Input Power  kW 0.91~2.41 1.01~3.12 1.21~3.95 1.33~4.69
COP - 3.23~3.80 3.15~3.81 3.15~3.61 3.05~3.89
Input Current A 2.56~11.52 4.83~14.93 5.78~18.89 6.36~22.45
Heating3 Output Capacity kW 4.11~10.37 5.10~13.25 6.25~14.63 7.52~16.57
Input Power  kW 0.74~2.28 0.94~13.73 1.14~3.12 1.37~3.56
COP - 4.55~5.56 4.61~5.42 4.69~5.46 4.66~5.47
Input Current A 3.54~10.91 4.50~12.49 5.45~14.93 6.55~17.03
Cooling4 Output Capacity kW 3.04~7.57 3.82~8.21 5.05~11.45 6.02~12.31
Input Power  kW 0.94~2.75 1.18~3.02 1.54~4.13 1.87~4.53
EER - 2.75~3.23 2.72~3.25 2.77~3.28 2.73~3.22
Input Current A 4.50~13.15 5.64~14.45 7.37~19.76 8.95~21.67
Power Supply  V/PH/HZ 220-240V/1/50Hz
ErP level(35ºC) - A+++ A+++ A+++ A+++
ErP level(55ºC) - A++ A++ A++ A++
Water Side Heat Exchanger  - Plate heat exchanger
Display controller  - LCD touch screen
Backup heater (Optional)  kW 3kW 
Expansion vessel - 5L
Refrigerant Type  - R32
Max Water Temperature
 (without backup heater)
ºC 60
Working Ambeint Temperature ºC -25~43
Water connection  inch G1-1/4
Sound pressure Level @1m  outdoor unit dB(A) 50 50 52 53
indoor unit dB(A) 27 27 27 27
Net Dimension (L*W*H)  outdoor unit mm 995*410*800 995*410*800 1065*410*960 1065*410*960
indoor unit mm 475*220*800 475*220*800 475*220*800 475*220*800
 
Market model   WW14VT-S WW16V-S WW18V-S WW20V-S WW22V-S
Heating1 Output Capacity kW 5.92~14.94 6.48~16.38 7.29~18.51 8.10~20.56 8.91~22.35
Input Power  kW 1.15~3.20 1.29~3.58 1.39~3.98 1.56~4.49 1.73~5.06
COP - 4.67~5.12 4.57~5.01 4.65~5.25 4.58~5.20 4.42~5.13
Input Current A 2.05~5.71 2.31~6.41 2.49~7.12 2.79~8.03 3.09~9.06
Heating2 Output Capacity kW 5.18~14.30 5.93~16.58 6.67~18.65 7.41~20.68 8.15~21.15
Input Power  kW 1.33~4.69 1.39~5.63 1.58~6.43 1.77~7.18 1.97~7.50
COP - 3.05~3.89 2.94~4.26 2.90~4.22 2.88~4.18 2.82~4.13
Input Current A 2.38~8.39 2.48~10.07 2.83~11.50 3.17~12.84 3.52~13.42
Heating3 Output Capacity kW 7.52~16.57 8.95~19.42 10.07~21.85 11.18~24.05 12.30~25.5
Input Power  kW 1.37~3.56 1.62~4.21 1.84~4.77 2.08~5.31 2.33~5.73
COP - 4.66~5.47 4.61~5.52 4.58~5.46 4.53~5.38 4.45~5.28
Input Current A 2.45~6.37 2.90~7.53 3.29~8.53 3.72~9.50 4.17~10.25
Cooling4 Output Capacity kW 6.02~12.31 7.23~14.82 8.13~15.72 9.03~16.67 9.93~17.50
Input Power  kW 1.87~4.53 2.27~5.43 2.64~5.86 3.00~6.36 3.35~6.78
EER - 2.73~3.22 2.73~3.18 2.68~3.08 2.62~3.01 2.58~2.96
Input Current A 3.34~8.10 4.06~9.71 4.72~10.48 5.37~11.38 6.00~12.13
Power Supply  V/PH/HZ 380-415V/3/50Hz
ErP level(35ºC) - A+++ A+++ A+++ A+++ A+++
ErP level(55ºC) - A++ A++ A++ A++ A++
Water Side Heat Exchanger  - Plate heat exchanger
Display controller  - LCD touch screen
Backup heater (Optional)  kW 3kW 
Expansion vessel - 5L
Refrigerant Type  - R32
Max Water Temperature
(without backup heater)
ºC 60
Working Ambeint Temperature ºC -25~43
Water connection  inch G1-1/4
Sound pressure Level @1m  outdoor unit dB(A) 53 56 56 58 58
indoor unit dB(A) 27 27 27 27 27
Net Dimension (L*W*H)  outdoor unit mm 1065*410*960 1065*410*960 1150*430*1350 1150*430*1350 1150*430*1350
indoor unit mm 475*220*800 475*220*800 475*220*800 475*220*800 475*220*800

Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.

Key Functions:
R32 environmental refrigerant
New Wotech heat pumps have been applied to the new gas solution of the R32 multifunction series.
The advantages are:
1.Compared to the R410A refrigerant, the R32 heat pump has a GWP of only one-third, so its environmental performance is even better.
2.High energy efficiency: It reaches A+++ energy level according to EU regulation. By harnessing the heat from the outside air, you use much less energy while still enjoying a steady and pleasant level of comfort. Maintenance requirements are minimal, keeping your running costs low. Thanks to inverter technology, your energy savings are even greater.

R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water

DHW tank disinfection
Maintain pristine quality of the water tank's DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 65C.
R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water



Climate cruve
With proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort level based on changing heat demand, insulation levels, etc. A constant monitoring of the current ambient temperature allows Wotech R32/R290 multifunction heat pump to adjust the outlet water temperature in the opposite direction to ensure the optimal level of comfort in the living space.
R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water

Floor preheating and drying
Protect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.

R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water
Powerful heating with high efficiency
1.No capacity attenuation at - 1OºC ambient temperature 
2.Operation range down to -25ºC
3.Maximum LWT reach 60ºC
4.Energy efficiency level: A+ + +

R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water
Mode combination

There are 4 single operation mode (Cool,Heat,DHW,Auto) and 3 combined operation mode to meet different demands of using.
R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water
Fast DHW

You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.
R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water
Additional control

1.Remote control for ON/OFFTBH,AHS
2.Balance tank temperature sensor(field supplied) ensures accurate water temperature control



Project Cases:
R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot WaterR32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water
Manufacturing & Laboratories
R32 Full DC Inverter a+++ 16kw Split Heat Pump Water Heater for Heating Cooling and Hot Water

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
175
Year of Establishment
2005-09-20