a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump

Product Details
Customization: Available
Certification: RoHS, CB, ISO9001, CE
Working Medium: R32
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
175
Year of Establishment
2005-09-20
  • a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
  • a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
  • a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
  • a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
  • a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
  • a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
Find Similar Products
  • Overview
  • Features
  • Two Heating circuits
  • Split Application Diagram
  • Technical Parameter
  • Key Functions:
  • Project cases
  • Manufacturing & Laboratories
Overview

Basic Info.

Model NO.
WW08-22VM/VT(R32 Split)
Thermostat Factory Setting
41/7
Thermostat Maximum Setting
60/5
Ambient Working Temperature
-30c~45c
Heating Capacity
8kw-16kw
Unit Type
Inverter
Application Scope
Hotels, Clubs, Hospitals, Villas and etc
Transport Package
Factory Standard
Specification
995*410*800mm
Trademark
Wotech
Origin
China
HS Code
84186120

Product Description


a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
Features

 

a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
Features:

1.Hot water up to 65ºC,suitable for underfloor/radiator heating/fan coil

2.With EVI system,can work stable at ambient temperature -25ºC to 45ºC

3.E-Heater,diverter valve and water pump can be inclueded

4. A+++ Energy Rating Level

5.Full inverter system,Stable and efficient performance.

6.R32 System,environment friendly

7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water

8.With Wifi App control
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump

a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat PumpInstallation Diagram:

a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
Two Heating circuits

 

a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
 
Two heating circuits

○ More flexibility thanks to two zones control

○ Independent temperature control of underfloor heating and radiator heating

○ User interface shows two different zones temperature


 
Split Application Diagram

a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump

Split Series Application Diagram

a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump

 
Technical Parameter

 

a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
 
Market model   WW08V-S WW10V-S WW12V-S WW14VM-S
Heating1 Output Capacity kW 3.40~8.65 3.70~10.30 4.95~12.46 5.92~14.94
Input Power  kW 0.59~1.65 0.62~2.05 0.90~2.48 1.15~3.20
COP - 5.23~5.72 5.02~5.90 5.03~5.50 4.67~5.12
Input Current A 2.82~7.92 2.96~9.81 4.31~11.85 5.50~15.3
Heating2 Output Capacity kW 3.43~7.77 3.90~9.84 4.37~12.43 5.18~14.30
Input Power  kW 0.91~2.41 1.01~3.12 1.21~3.95 1.33~4.69
COP - 3.23~3.80 3.15~3.81 3.15~3.61 3.05~3.89
Input Current A 2.56~11.52 4.83~14.93 5.78~18.89 6.36~22.45
Heating3 Output Capacity kW 4.11~10.37 5.10~13.25 6.25~14.63 7.52~16.57
Input Power  kW 0.74~2.28 0.94~13.73 1.14~3.12 1.37~3.56
COP - 4.55~5.56 4.61~5.42 4.69~5.46 4.66~5.47
Input Current A 3.54~10.91 4.50~12.49 5.45~14.93 6.55~17.03
Cooling4 Output Capacity kW 3.04~7.57 3.82~8.21 5.05~11.45 6.02~12.31
Input Power  kW 0.94~2.75 1.18~3.02 1.54~4.13 1.87~4.53
EER - 2.75~3.23 2.72~3.25 2.77~3.28 2.73~3.22
Input Current A 4.50~13.15 5.64~14.45 7.37~19.76 8.95~21.67
Power Supply  V/PH/HZ 220-240V/1/50Hz
ErP level(35ºC) - A+++ A+++ A+++ A+++
ErP level(55ºC) - A++ A++ A++ A++
Water Side Heat Exchanger  - Plate heat exchanger
Display controller  - LCD touch screen
Backup heater (Optional)  kW 3kW 
Expansion vessel - 5L
Refrigerant Type  - R32
Max Water Temperature
 (without backup heater)
ºC 60
Working Ambeint Temperature ºC -25~43
Water connection  inch G1-1/4
Sound pressure Level @1m  outdoor unit dB(A) 50 50 52 53
indoor unit dB(A) 27 27 27 27
Net Dimension (L*W*H)  outdoor unit mm 995*410*800 995*410*800 1065*410*960 1065*410*960
indoor unit mm 475*220*800 475*220*800 475*220*800 475*220*800
 
Market model   WW14VT-S WW16V-S WW18V-S WW20V-S WW22V-S
Heating1 Output Capacity kW 5.92~14.94 6.48~16.38 7.29~18.51 8.10~20.56 8.91~22.35
Input Power  kW 1.15~3.20 1.29~3.58 1.39~3.98 1.56~4.49 1.73~5.06
COP - 4.67~5.12 4.57~5.01 4.65~5.25 4.58~5.20 4.42~5.13
Input Current A 2.05~5.71 2.31~6.41 2.49~7.12 2.79~8.03 3.09~9.06
Heating2 Output Capacity kW 5.18~14.30 5.93~16.58 6.67~18.65 7.41~20.68 8.15~21.15
Input Power  kW 1.33~4.69 1.39~5.63 1.58~6.43 1.77~7.18 1.97~7.50
COP - 3.05~3.89 2.94~4.26 2.90~4.22 2.88~4.18 2.82~4.13
Input Current A 2.38~8.39 2.48~10.07 2.83~11.50 3.17~12.84 3.52~13.42
Heating3 Output Capacity kW 7.52~16.57 8.95~19.42 10.07~21.85 11.18~24.05 12.30~25.5
Input Power  kW 1.37~3.56 1.62~4.21 1.84~4.77 2.08~5.31 2.33~5.73
COP - 4.66~5.47 4.61~5.52 4.58~5.46 4.53~5.38 4.45~5.28
Input Current A 2.45~6.37 2.90~7.53 3.29~8.53 3.72~9.50 4.17~10.25
Cooling4 Output Capacity kW 6.02~12.31 7.23~14.82 8.13~15.72 9.03~16.67 9.93~17.50
Input Power  kW 1.87~4.53 2.27~5.43 2.64~5.86 3.00~6.36 3.35~6.78
EER - 2.73~3.22 2.73~3.18 2.68~3.08 2.62~3.01 2.58~2.96
Input Current A 3.34~8.10 4.06~9.71 4.72~10.48 5.37~11.38 6.00~12.13
Power Supply  V/PH/HZ 380-415V/3/50Hz
ErP level(35ºC) - A+++ A+++ A+++ A+++ A+++
ErP level(55ºC) - A++ A++ A++ A++ A++
Water Side Heat Exchanger  - Plate heat exchanger
Display controller  - LCD touch screen
Backup heater (Optional)  kW 3kW 
Expansion vessel - 5L
Refrigerant Type  - R32
Max Water Temperature
(without backup heater)
ºC 60
Working Ambeint Temperature ºC -25~43
Water connection  inch G1-1/4
Sound pressure Level @1m  outdoor unit dB(A) 53 56 56 58 58
indoor unit dB(A) 27 27 27 27 27
Net Dimension (L*W*H)  outdoor unit mm 1065*410*960 1065*410*960 1150*430*1350 1150*430*1350 1150*430*1350
indoor unit mm 475*220*800 475*220*800 475*220*800 475*220*800 475*220*800

Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.

 
Key Functions:

 

a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump

R32 environmental refrigerant

1. R32 has a GWP of 675, roughly 30% lower than that of R410A
2. R32 systems use up to 20% less refrigerant than R410A, making them more efficient and cost less to operate
3. Ozone Depletion Potential of 0
4. Easier to recycle than R410A, as R32 is a single component refrigerant
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump

DHW tank disinfection

The DHW tank disinfection function is used to kill legionella by 65°C water to ensure the health and safety.
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump

Smart control system:

1. Smart logic to run between hot water and domestic heating, satisfying different heat demands.
 
2. 8 different languages available, user-friendly for many countries.
 
3. Combination of multi-heat source, E-heater, solar panel or boiler etc, heat your house intelligently.
 
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
 

Powerful heating with high efficiency

 
1. Little capacity attenuation at -10°C ambient temperature.
2. Operation temperature down to -25°C, reliable system guarantees a warm winter.
3. Maximum LWT upto 60°C, more efficient for radiator users.
4. Energy efficiency level: W35 A+++/ W55 A++, complying EU with standard.
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump

ECO mode:

Once ECO mode is slected, the unit sets the outlet water temperature automatically according to the outdoor ambient air temperature. function.
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump


Wifi App Control:

1. Control your heat pump wherever you are.
2. Pay less bills by setting weekly timer.  
3. Real-time monitoring heat pumps online .
4. Immediate alarm on system faults or protections, easy found easy solved.
5. Easy access for service by modifying 100 + parameters settings online.
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump

Inverter Technology:
Full DC inverter technology is adopted to ensure fast start, avoid frequent start and stop, low noise, high energy efficiency.
 
1. DC Inverter Compressor
Intelligently match the operating frequency according to the load, and intelligently output on demand

2. DC Fan Motor
Stepless speed adjustment, intelligently matching air volume according to system requirements
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
 
Project cases

 

a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
Wotech Project cases:
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pumpa+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pumpa+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
 
Manufacturing & Laboratories

 

a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump
Manufacturing & Laboratories
a+++ Made in China EU CB/CE Standard Full DC Inverter Air Source Heat Pump





 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier