Customization: | Available |
---|---|
Certification: | RoHS, CB, ISO9001, CE |
Heat Source Type: | Air Source Heat Pump |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Code | WBC-9.5HP-B | WBC-16.0HP-B | WBC-19.0HP-B | WBC-19.0HP-B-S | WBC-22.0HP-B | WBC-22.0HP-B-S | WBC-32.0HP-B-S | ||
Heating Working Condition A -12/-14ºC W 36-41ºC |
Output Capacity | Kw | 5.4 | 10 | 12 | 12.09 | 14.4 | 14.83 | 20.3 |
COP | - | 2.41 | 2.45 | 2.37 | 2.33 | 2.40 | 2.65 | 2.2 | |
Input Power | Kw | 2.24 | 4.08 | 5.06 | 5.19 | 6.00 | 5.60 | 9.23 | |
Input Current | A | 10.72 | 19.52 | 24.21 | 9.28 | 28.71 | 10.01 | 16.51 | |
Heating Working Condition A 7/6ºC W 40-45ºC |
Output Capacity | Kw | 9.5 | 16.10 | 19.10 | 19.30 | 22.00 | 22.63 | 32.00 |
COP | - | 3.10 | 3.40 | 3.10 | 3.12 | 3.13 | 3.15 | 3.13 | |
Input Power | Kw | 3.06 | 4.73 | 6.17 | 6.19 | 7.04 | 7.18 | 10.22 | |
Input Current | A | 14.64 | 22.63 | 29.52 | 11.07 | 33.68 | 12.85 | 18.29 | |
Cooling Working Condition A -20/-21ºC W 36-41ºC |
Output Capacity | Kw | 3.99 | 8.20 | 10.10 | 9.74 | 11.70 | 12.16 | 16.80 |
COP | - | 1.92 | 2.10 | 2.04 | 1.97 | 2.13 | 2.13 | 2.08 | |
Input Power | Kw | 2.08 | 3.90 | 4.95 | 4.95 | 5.49 | 5.71 | 8.08 | |
Input Current | A | 9.94 | 18.66 | 23.68 | 8.75 | 26.27 | 10.21 | 14.45 | |
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380V/3/50HZ | 230V/1/50HZ | 380V/3/50HZ | ||||
Water Flow Rate(ΔT 5ºC) | m³/h | 1.63 | 2.77 | 3.28 | 3.32 | 3.78 | 3.89 | 5.50 | |
Thermostat Factory Setting | ºC | 41/7 | |||||||
Max Water Temperature | ºC | 60/5 | |||||||
water pressure loss | Kpa | 40 | 40 | 40 | 40 | 40 | 40 | 60 | |
Water connection | inch | G1" | G1-1/2" | ||||||
Sound pressure Level @1m | dB(A) | 58 | 58 | 60 | 60 | 60 | 60 | 65 | |
Net Dimension (L*W*H) | mm | 995*410*800 | 1070*390*1330 | 1138*430*1550 | |||||
Remarks:The Specifications are subject to changes without notice. |