Customization: | Available |
---|---|
Certification: | RoHS, CB, ISO9001, CE |
Working Medium: | R410A |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Market model | WW09V | WW14V | WW18V | WW25V | WW30V | ||
Heating Working Condition A 7ºC/ 6ºC W 30-35ºC |
Output Capacity | Kw | 9.8 | 14 | 18.4 | 25.3 | 30.1 |
Input Power | Kw | 2.4 | 3.3 | 4.3 | 6.2 | 5.3 | |
COP | - | 10.6 | 5.9 | 7.1 | 11.3 | 12.6 | |
Input Current | A | 4.1 | 4.3 | 4.3 | 4.1 | 4 | |
Heating Working Condition A 20ºC/ 15ºC W 40-45ºC |
Output Capacity | Kw | 11.3 | 18.4 | 21.8 | 29.5 | 36.2 |
Input Power | Kw | 2.9 | 4.6 | 5.2 | 7.4 | 9.3 | |
COP | - | 13 | 7.8 | 8.4 | 12.7 | 15.4 | |
Input Current | A | 3.9 | 4 | 4.2 | 4 | 3.9 | |
Cooling Working Condition A 35ºC/ 25ºC W 12-7ºC |
Output Capacity | Kw | 6.7 | 10.4 | 13.1 | 19.3 | 22.4 |
Input Power | Kw | 2.6 | 3.8 | 5.1 | 7.3 | 8.1 | |
COP | - | 11.3 | 6.8 | 8.5 | 12.6 | 13.6 | |
Input Current | A | 2.6 | 2.7 | 2.6 | 2.7 | 2.8 | |
Power Supply | V/PH/HZ | 220V/1/50HZ | 380V/3/50HZ | 380V/3/50HZ | 380V/3/50HZ | 380V/3/50HZ | |
Electric heater | Kw | 1.5 | 4 | 4 | 6 | 6 | |
internal expansion tank size | L | 5 | 8 | 8 | 12 | 12 | |
Refrigerant Type | - | R410A | R410A | R410A | R410A | R410A | |
Max Water Temperature | ºC | 60 | 60 | 60 | 60 | 60 | |
Working Ambeint Temperature | ºC | -10~43 | -10~43 | -10~43 | -10~43 | -10~43 | |
Water Flow Rate(ΔT 5ºC) | m³/h | 2 | 2.7 | 3.7 | 5.2 | 6.2 | |
Water connection | inch | G1" | G1" | G1" | G1.5" | G1.5" | |
Circulation pump | pcs | 1 | 1 | 1 | 1 | 1 | |
Compressor number | pcs | 1 | 1 | 1 | 1 | 1 | |
Fan number | pcs | 1 | 1 | 2 | 2 | 2 | |
Sound pressure Level @1m | dB(A) | 54 | 56 | 57 | 58 | 58 | |
Net Dimension (L*W*H) | mm | 1165*410*800 | 1165*410*1000 | 1150*440*1350 | 1165*430*1550 | 1165*430*1550 |