12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water

Product Details
Customization: Available
Certification: RoHS, CB, ISO9001, CE
Working Medium: R32
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
175
Year of Establishment
2005-09-20
  • 12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water
  • 12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water
  • 12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water
  • 12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water
  • 12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water
  • 12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water
Find Similar Products

Basic Info.

Model NO.
WWR32V
Heat Source Type
Air Source Heat Pump
Thermostat Factory Setting
41/7
Thermostat Maximum Setting
60/5
Ambient Working Temperature
-30c~45c
Heating Capacity
8kw-16kw
Unit Type
Inverter
Application Scope
Hotels,Clubs,Hospitals,Villas and etc
Transport Package
Factory Standard
Specification
995*410*800mm
Trademark
Wotech
Origin
China
HS Code
84186120

Product Description

12KW R32 Full DC Inverter A+++ Monoblock Heat Pump Water Heater for heating cooling and hot water
Features:

1.Hot water up to 65ºC,suitable for underfloor/radiator heating/fan coil

2.Can work stable at ambient temperature -25C to 45C

3.E-Heater,diverter valve and water pump can be inclueded

4. A+++ Energy Rating Level

5.Full inverter system,Stable and efficient performance.

6.R32 System,environment friendly

7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water

8.With Wifi App control
12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water

Installation Diagram:
12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water 

Technical Parameter
Market model   WW08V WW10V WW12V WW14VM
Heating1 Output Capacity kW 3.40~8.65 3.70~10.30 4.95~12.46 5.92~14.94
Input Power  kW 0.59~1.65 0.62~2.05 0.90~2.48 1.15~3.20
COP - 5.23~5.72 5.02~5.90 5.03~5.50 4.67~5.12
Input Current A 2.82~7.92 2.96~9.81 4.31~11.85 5.50~15.3
Heating2 Output Capacity kW 3.43~7.77 3.90~9.84 4.37~12.43 5.18~14.30
Input Power  kW 0.91~2.41 1.01~3.12 1.21~3.95 1.33~4.69
COP - 3.23~3.80 3.15~3.81 3.15~3.61 3.05~3.89
Input Current A 2.56~11.52 4.83~14.93 5.78~18.89 6.36~22.45
Heating3 Output Capacity kW 4.11~10.37 5.10~13.25 6.25~14.63 7.52~16.57
Input Power  kW 0.74~2.28 0.94~13.73 1.14~3.12 1.37~3.56
COP - 4.55~5.56 4.61~5.42 4.69~5.46 4.66~5.47
Input Current A 3.54~10.91 4.50~12.49 5.45~14.93 6.55~17.03
Cooling4 Output Capacity kW 3.04~7.57 3.82~8.21 5.05~11.45 6.02~12.31
Input Power  kW 0.94~2.75 1.18~3.02 1.54~4.13 1.87~4.53
EER - 2.75~3.23 2.72~3.25 2.77~3.28 2.73~3.22
Input Current A 4.50~13.15 5.64~14.45 7.37~19.76 8.95~21.67
Power Supply  V/PH/HZ 220-240V/1/50Hz
ErP level(35ºC) - A+++ A+++ A+++ A+++
ErP level(55ºC) - A++ A++ A++ A++
Water Side Heat Exchanger  - Plate heat exchanger
Display controller  - LCD touch screen
Backup heater (Optional)  kW 3kW 
Expansion vessel / 5L
Refrigerant Type  - R32
Max Water Temperature
(without backup heater)
ºC 60
Working Ambeint Temperature ºC -25~43
Water connection  inch G1-1/4
Sound pressure Level @1m  dB(A) 50 50 52 53
Net Dimension (L*W*H)  mm 995*410*800 995*410*800 1065*410*960 1065*410*960
Market model   WW14VT WW16V WW18V WW20V WW22V
Heating1 Output Capacity kW 5.92~14.94 6.48~16.38 7.29~18.51 8.10~20.56 8.91~22.35
Input Power  kW 1.15~3.20 1.29~3.58 1.39~3.98 1.56~4.49 1.73~5.06
COP - 4.67~5.12 4.57~5.01 4.65~5.25 4.58~5.20 4.42~5.13
Input Current A 2.05~5.71 2.31~6.41 2.49~7.12 2.79~8.03 3.09~9.06
Heating2 Output Capacity kW 5.18~14.30 5.93~16.58 6.67~18.65 7.41~20.68 8.15~21.15
Input Power  kW 1.33~4.69 1.39~5.63 1.58~6.43 1.77~7.18 1.97~7.50
COP - 3.05~3.89 2.94~4.26 2.90~4.22 2.88~4.18 2.82~4.13
Input Current A 2.38~8.39 2.48~10.07 2.83~11.50 3.17~12.84 3.52~13.42
Heating3 Output Capacity kW 7.52~16.57 8.95~19.42 10.07~21.85 11.18~24.05 12.30~25.5
Input Power  kW 1.37~3.56 1.62~4.21 1.84~4.77 2.08~5.31 2.33~5.73
COP - 4.66~5.47 4.61~5.52 4.58~5.46 4.53~5.38 4.45~5.28
Input Current A 2.45~6.37 2.90~7.53 3.29~8.53 3.72~9.50 4.17~10.25
Cooling4 Output Capacity kW 6.02~12.31 7.23~14.82 8.13~15.72 9.03~16.67 9.93~17.50
Input Power  kW 1.87~4.53 2.27~5.43 2.64~5.86 3.00~6.36 3.35~6.78
EER - 2.73~3.22 2.73~3.18 2.68~3.08 2.62~3.01 2.58~2.96
Input Current A 3.34~8.10 4.06~9.71 4.72~10.48 5.37~11.38 6.00~12.13
Power Supply  V/PH/HZ 380-415V/3/50Hz
ErP level(35ºC) - A+++ A+++ A+++ A+++ A+++
ErP level(55ºC) - A++ A++ A++ A++ A++
Water Side Heat Exchanger  - Plate heat exchanger
Display controller  - LCD touch screen
Backup heater (Optional)  kW 3kW 
Expansion vessel / 5L
Refrigerant Type  - R32
Max Water Temperature
(without backup heater)
ºC 60
Working Ambeint Temperature ºC -25~43
Water connection  inch G1-1/4
Sound pressure Level @1m  dB(A) 53 56 56 58 58
Net Dimension (L*W*H)  mm 1065*410*960 1065*410*960 1150*430*1350 1150*430*1350 1150*430*1350

 Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.

Key Functions:
12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water


Project Cases:
12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water
Manufacturing & Laboratories
12kw R32 Full DC Inverter a+++ Monoblock Air Source Heat Pump Water Heater for Heating Cooling and Hot Water

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier