R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water

Product Details
Customization: Available
Certification: ISO9001, CE
Thermostat Factory Setting: 41/7
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
175
Year of Establishment
2005-09-20
  • R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water
  • R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water
  • R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water
  • R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water
  • R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water
  • R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water
Find Similar Products

Basic Info.

Model NO.
WWR290-V
Ambient Working Temperature
-30c~45c
Heating Capacity
4kw-16kw
Unit Type
Inverter
Application Scope
Hotels,Clubs,Hospitals,Villas and etc
Transport Package
Factory Standard
Specification
1050*410*950mm
Trademark
Wotech
Origin
China
HS Code
84186120

Product Description

R290 Full DC Inverter a+++ Air to Water Monoblock Heat Pump for Heating Cooling and Hot Water
Features:

1.Hot water up to 70C,suitable for underfloor/radiator heating/fan coil

2.can work stable at ambient temperature -25C to 45C

3.E-Heater,diverter valve and water pump can be inclueded

4. A+++ Energy Rating Level

5.Full inverter system,Stable and efficient performance.

6.R290 System,environment friendly

7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water

8.With Wifi App control
R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water

Installation Diagram:
 
R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water

Technical Parameter
Market model   WW07VM WW09VM WW12VM WW15VM WW20VT WW22VT
Heating1
A7 W35
Output Capacity kW 2.84~7.20 3.61~9.17 4.75~12.06 5.83~14.80 8.03~20.38 8.71~22.12
Input Power  kW 0.51~1.58 0.67~2.07 0.87~2.67 1.09~3.36 1.50~4.62 1.66~5.09
COP - 4.56~5.52 4.43~5.36 4.51~5.46 4.40~5.32 4.41~5.34 4.35~5.26
Input Current A 2.35~7.23 3.08~9.47 3.98~12.24 5.01~15.39 2.69~8.27 2.96~9.10
Heating2
A7 W55
Output Capacity kW 2.60~6.83 3.27~8.60 4.51~11.88 5.41~14.24 7.49~19.72 8.29~21.82
Input Power  kW 0.72~2.24 0.94~2.91 1.26~3.92 1.57~4.88 2.08~6.44 2.41~7.47
COP - 3.05~3.60 2.96~3.49 3.03~3.58 2.92~3.45 3.06~3.61 2.92~3.45
Input Current A 3.30~10.25 4.28~13.30 5.78~17.94 7.19~22.32 3.71~11.53 4.30~13.37
Heating3
A20 W55
Output Capacity kW 3.54~8.86 4.47~11.19 5.98~14.95 7.16~17.91 10.03~25.07 10.71~26.77
Input Power  kW 0.69~2.01 0.88~2.57 1.15~3.38 1.40~4.11 1.96~5.72 2.13~6.24
COP - 4.41~5.16 4.36~5.10 4.43~5.18 4.36~5.10 4.38~5.12 4.29~5.02
Input Current A 3.14~9.19 4.01~11.74 5.28~15.45 6.43~18.80 3.50~10.24 3.82~11.16
Cooling4
A35 W7
Output Capacity kW 2.11~5.02 2.95~7.03 3.83~9.12 4.45~10.59 5.90~14.05 6.38~15.20
Input Power  kW 0.67~1.89 0.98~2.76 1.30~3.65 1.58~4.45 1.98~5.58 2.24~6.31
EER - 2.65~3.13 2.55~3.01 2.50~2.95 2.38~2.81 2.52~2.97 2.41~2.84
Input Current A 3.09~8.67 4.49~12.62 5.94~16.70 7.25~20.36 3.55~9.97 4.02~11.28
Power Supply  V/PH/HZ 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 380-415V/3/50Hz 380-415V/3/50Hz
ErP level(35ºC) - A+++ A+++ A+++ A+++ A+++ A+++
ErP level(55ºC) - A++ A++ A++ A++ A++ A++
Water Side Heat Exchanger   - Plate heat exchanger Plate heat exchanger Plate heat exchanger Plate heat exchanger Plate heat exchanger Plate heat exchanger
Display controller  - LCD touch screen LCD touch screen LCD touch screen LCD touch screen LCD touch screen LCD touch screen
Backup heater (Optional)  kW 3kW  3kW  3kW  3kW  3kW  3kW 
Expansion vessel / 3L 3L 5L 5L 5L 5L
Refrigerant Type  - R290 R290 R290 R290 R290 R290
Max Oulet Water Temperature ºC 75 75 75 75 75 75
Working Ambeint Temperature ºC -25~43 -25~43 -25~43 -25~43 -25~43 -25~43
Water connection  inch G1-1/4 G1-1/4 G1-1/4 G1-1/4 G1-1/4 G1-1/4
Sound pressure Level @1m  dB(A) 50 50 52 53 58 58
Net Dimension (L*W*H)  mm 1085*440*840 1085*440*840 1150*430*960 1150*430*960 1150*430*1400  1150*430*1400 
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC. 
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825


Key Functions:
R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot WaterR290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water


Project Cases:
R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot WaterR290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water
Manufacturing & Laboratories
R290 Full DC Inverter a+++ Monoblock System Air to Water Heat Pump for Heating Cooling and Hot Water

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier